MIL-DTL-2427H (AR)
Conformance inspection by classification of characteristics
PARAGRAPH
TITLE
DRAWING NUMBER
4.3.2.1
Assembly
drawing indicated by
SHEET 3 OF 7
contract
NEXT HIGHER ASSEMBLY
EXAMINATION OR TEST
Grade
CONFORMANCE
REQUIREMENT
INSPECTION METHOD
CLASSIFICATION
A
B
C
CRITERIA
PARAGRAPH
REFERENCE
Major
119
x
x
Markings misleading or unidentifiable
Level IV
3.9
Visual
120
x
x
x Repair plug above surface or
improperly secured
Level IV
3.3.3.1
Visual
121
x
x
x Nail not clinched
Level IV
3.8.1
Visual
122
x
x
x Nail not of type or size required
Level IV
3.7.1/3.7.2
SME/Visual
123
x
x
Rope end not visible at cleat groove
Level IV
3.4
Visible
124
x
x
Nails not driven into centerline of
cleat and over centerlines of grooves
as shown in Figure 1
Level IV
3.7.3
Visible
Minor
201
x
x
x Inside height, max
Level II
See (*)
SME
202
x
x
x Inside length, max
Level II
See (*)
SME
203
x
x
x Inside width, max
Level II
See (*)
SME
*. Dimensions shall be specified by drawings indicated by contract