MIL-DTL-45449C
4.3.3.2
Pallet assembly.
Conformance
Criteria
Requirement
Inspection
Classification
Examination or test
Grade Grade
Paragraph
Method
A
B
None Defined
Critical
Major
101
Dimensional requirements not
VL IV
VL II
3.8.3
AIE
in conformance with applicable
drawings (See 6.10)
102
Pallet not dimensionally square
VL IV
VL II
3.12
AIE
and accurately formed
103
Size and location of counter
VL IV
VL II
3.8.3
AIE
bores
104
Splits or season checks on base
VL IV
3.8.4.2/
Visual
deck board, cover deck board
3.8.4.3/
and cover cleat
3.8.4.4
105
Size or type of nails incorrect
VL IV
VL II
3.9.1
Visual
106
Nailing requirements not in
VL IV
VL II
3.9.1/ 3.9.2/
Visual
conformance with applicable
3.9.3
drawings (See 6.10)
107
Moisture content
15
15
3.4
4.4.1/
4.4.2/ 4.4.3
108
U-Bolt requirements not in
VL II
VL I
3.11
AIE
conformance with 13029014
(if applicable)
109
Linderman jointed pieces
15
3.7
4.5/ 4.5.1
110
ISPM heat treatment marking
VL IV
VLII
3.14.2
Visual
111
Presence of wood preservative
15
3.13/ 3.13.1
4.6
17