MIL-DTL-18492B (OS)
used for all characteristics defined as Majors and Verification Level II for all Minor characteristics;
Critical characteristics shall be addressed in accordance with MIL-STD-1916. In addition to the sampling
requirements stated herein, Verification Level VII shall be used to verify the 100% screening operation of
Critical Characteristics.
4.2.1 Lot size. The term "lot" shall mean "inspection lot" i.e., a collection of units of product submitted
by a supplier for Government inspection. Sampling plans and procedures when applicable in
determination of the acceptability of the lots or products procured by the Government, unless otherwise
specified, shall conform to the provisions of MIL-STD-1916.
Unless otherwise specified in the contract or purchase order, the production lot shall consist of maximum
of 1000 complete tanks and/or cover assemblies plus those required for test purposes. Unless otherwise
specified in the contract or purchase order, all tanks and cover assemblies for inspection purposes shall be
provided at the expense of the supplier.
4.2.2 Production sample.
4.2.2.1 Tank assemblies. A preproduction sample of 10 complete tanks with covers, five painted and five
unpainted, shall be submitted to a facility designated by the procuring activity for inspection and testing
in accordance with Table I to determine conformance to the technical requirements of the contract.
Further production of the tank and cover by the supplier, prior to approval of the preproduction sample,
shall be at the supplier's risk.
4.2.2.2 Cover assemblies. A preproduction sample of 10 covers assemblies, five painted and five
unpainted, shall be submitted to a facility designated by the procuring activity for inspection and testing
in accordance with Table I to determine conformance to the technical requirements of the contract.
Further production of the cover assembly by the supplier, prior to approval of the preproduction sample,
shall be at the supplier's risk.
4.2.3 Quality conformance inspection sampling. Samples shall be selected and inspected in accordance
with Tables I and II to determine the acceptability of the tank and cover, or the cover assembly.